The AUDAC TR106 is a shielded true isolation audio transformer. Hum in audio systems is usually caused by ground loops in the system. A common mode current will flow in a ground loop created by an electrical system that has grounds on different voltage potentials. This results in a 50 Hz hum in the audio signal. The most common method to solve these problems is an audio transformer. The AUDAC TR106 audio isolation transformer with an in- and output impedance of 600 Ohm and a turns ratio of 1 : 1 has a very wide bandwidth and very low distortion which ensures a non distorted bass response and non attenuated high frequencies.
SYSTEM SPECIFICATIONS | ||||
---|---|---|---|---|
Inputs | Impedance | 600 Ω | ||
Max level at 1% THD+N (@ 1 kHz) | 20 Hz | +2 dBu (0.975V) | ||
50 Hz | +10 dBu (2.449V) | |||
Outputs | Impedance | 600 Ω | ||
Turn ratio | 1 : 1 | |||
Bandwidth | 0.5 Hz – 100 kHz | |||
Typical distortion (@ 1 kHz) | 0.001% | |||
Frequency | High cutoff (± 3 dB) | 108 kHz | ||
Low cutoff (± 3 dB) | 0.4 Hz | |||
Response (± 3 dB) | 20 Hz | -0.10 dB (reference 1 kHz) | ||
20 kHz | -0.10 dB (reference 1 kHz) | |||
THD+N (@ 20 Hz) | 0.05% | |||
THD+N (@ 1 kHz) | 0.001% |
PRODUCT FEATURES | ||||
---|---|---|---|---|
Dimensions | 17 x 17.2 x 16.5 mm (W x H x D) |
INFORMATION SHEETS